International Journal For Multidisciplinary Research

E-ISSN: 2582-2160     Impact Factor: 9.24

A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal

Call for Paper Volume 7, Issue 4 (July-August 2025) Submit your research before last 3 days of August to publish your research paper in the issue of July-August.

Complications in Atrial Septal Defect Device Closure: Case Study

Author(s) Dr. Amitabh Verma, Dr. Santosh Pandey
Country India
Abstract Atrial septal defect (ASD) is a common congenital cardiac anomaly. Even though surgery is the gold standard, percutaneous device closure is gaining popularity because of the short learning curve, cosmetic advantage and relative safety. The long-term implications are open to question. We report here two paediatric cases where surgical intervention was required during attempted percutaneous closure and briefly review the relevant literature. The atrial septal defect device closure was done in both the cases using a Amplatzer Device and delivery system, guided by Trans Esophageal Echocardiography (TEE).
Keywords Atrial septal defect (ASD); Amplatzer Device; Trans Esophageal Echocardiography (TEE), paediatric cases
Field Medical / Pharmacy
Published In Volume 7, Issue 4, July-August 2025
Published On 2025-08-09
DOI https://doi.org/10.36948/ijfmr.2025.v07i04.53038
Short DOI https://doi.org/g9w5hx

Share this