International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
Conferences Published ↓
ISC-AISGF-TBRF
DePaul-2026
IC-AIRCM-T3-2026
NSSFIGTMA-2025
SPHERE-2025
AIMAR-2025
SVGASCA-2025
ICRTET-4
ICCE-2025
Chinai-2023
PIPRDA-2023
ICMRS'23
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 8 Issue 6
November-December 2026
Indexing Partners
An Integrated Multi-Variable Analytical Framework for Coupled Cannabinoid Extraction and Neurodegenerative Protein Spectroscopy in a Unified Laboratory System
| Author(s) | Joshua Blessing Animasaun, Damilola Ogunmola, Olatayo Olahanmi |
|---|---|
| Country | United States |
| Abstract | Conventional biochemical analysis workflows for cannabinoid extraction and neurodegenerative protein spectroscopy rely on multiple discrete instruments, resulting in increased processing time, higher contamination risk, and reduced data consistency. This paper presents a unified analytical framework that integrates extraction and spectroscopic analysis within a single laboratory platform. The proposed system combines thermal, pressure, fluidic, and optical subsystems under a centralized control architecture to enable synchronized operation and real-time data acquisition. A multi-variable experimental design was implemented to evaluate system performance using key parameters including temperature (60–78 °C), pressure (3.5–6.0 bar), extraction time (20–45 min), solvent flow rate (0.8–1.8 L/min), spectral intensity (650–980 a.u.), signal-to-noise ratio (30–55), and extraction yield (60–90%). Experimental results indicate that the integrated system reduces total processing time by approximately 45% compared to conventional multi-instrument workflows while achieving maximum extraction yield of 88–90% under optimal operating conditions (72–74 °C and 5.0–5.5 bar). Spectroscopic performance is improved, with signal-to-noise ratio exceeding 45 in optimized runs, indicating enhanced signal clarity and measurement reliability. The developed multi-variable regression model demonstrates strong predictive capability with coefficient of determination (R²) of 0.91, root mean square error (RMSE) of 3.8, and mean absolute error (MAE) of 2.9. Furthermore, the system exhibits high reproducibility, with less than 5% variation across repeated trials. The results confirm that integrating extraction and spectroscopy within a unified platform improves efficiency, analytical accuracy, and operational stability. The proposed framework provides a scalable and data-driven approach for advanced biochemical analysis and offers significant potential for applications in biomedical research, pharmaceutical development, and laboratory automation. |
| Keywords | Integrated Analytical System, Cannabinoid Extraction, Protein Spectroscopy, Multi-Variable Modeling, Signal-to-Noise Ratio, Process Optimization, Laboratory Instrumentation. |
| Published In | Volume 7, Issue 6, November-December 2025 |
| Published On | 2025-12-27 |
| DOI | https://doi.org/10.36948/ijfmr.2025.v07i06.72776 |
Share this

E-ISSN 2582-2160
CrossRef DOI prefix of IJFMR is 10.36948/ijfmr
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
Powered by Sky Research Publication and Journals