International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
Conferences Published ↓
DePaul-2026
IC-AIRCM-T3-2026
NSSFIGTMA-2025
SPHERE-2025
AIMAR-2025
SVGASCA-2025
ICRTET-4
ICCE-2025
Chinai-2023
PIPRDA-2023
ICMRS'23
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 8 Issue 5
September-October 2026
Indexing Partners
Radiomics in Precision Medicine: Barriers to Clinical Translation - A Critical Analysis
| Author(s) | Mr. Ashish Yadav, Ms. Mitali Monalisha, Ms. Priya Yadav, Ms. Saman Khan, Ms. Harjeet Kaur, Ms. Neha Raj |
|---|---|
| Country | India |
| Abstract | Background & Objective Radiomics — the high-throughput extraction of quantitative imaging features — holds transformative potential for precision oncology, enabling non-invasive phenotyping, treatment stratification, and prognostic prediction. Despite exponential growth in publications, fewer than 5% of radiomic biomarkers achieve clinical integration. This critical analysis systematically examines the principal barriers impeding translation, with particular emphasis on standardization deficits and reproducibility failures that undermine scientific validity. Methods & Scope A narrative critical synthesis was performed across Scopus-indexed literature (2014–2024), encompassing landmark multi-site radiomic reproducibility studies, imaging biomarker standardization initiatives (IBSI, QIBA, RQS), and regulatory framework assessments. Data from 47 representative studies spanning lung, head-and-neck, brain, and breast oncology were analysed to characterize feature stability, inter-software agreement, and external validation performance. Key Findings Intraclass correlation coefficients (ICCs) for texture features across scanners ranged from 0.31 to 0.89, with GLSZM and NGTDM features showing the poorest inter-site reproducibility (mean ICC 0.44-0.49). Model AUC degraded an average of 22 percentage points (range 17-27%) upon external validation. Post-IBSI implementation improved cross-software feature agreement from a mean of 34.6% to 79.4% — yet full adoption remains incomplete. Segmentation variability alone accounted for 27% of reproducibility variance. Conclusion & Keywords Radiomics translation requires a paradigm shift from discovery-centric to validation-centric practice, underpinned by mandatory harmonization protocols, prospective multi-site designs, and regulatory co-development. |
| Keywords | Radiomics; Reproducibility; Standardization; IBSI; Precision Medicine; Imaging Biomarkers; ICC; Clinical Translation |
| Field | Medical / Pharmacy |
| Published In | Volume 8, Issue 5, September-October 2026 |
| Published On | 2026-09-04 |
| DOI | https://doi.org/10.36948/ijfmr.2026.v08i05.87117 |
Share this

E-ISSN 2582-2160
CrossRef DOI prefix of IJFMR is 10.36948/ijfmr
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
Powered by Sky Research Publication and Journals