International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
Conferences Published ↓
ISC-AISGF-TBRF
DePaul-2026
IC-AIRCM-T3-2026
NSSFIGTMA-2025
SPHERE-2025
AIMAR-2025
SVGASCA-2025
ICRTET-4
ICCE-2025
Chinai-2023
PIPRDA-2023
ICMRS'23
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 8 Issue 5
September-October 2026
Indexing Partners
Enhanced Voltage Recovery Strategy for DFIG Based Wind Farms Under Grid Fault Conditions
| Author(s) | Mr. Rushikesh Virendrabhai Pandya, Mr. Hardik Vinodbhai Vanpariya, Mr. Ronit Dineshbhai Rakahdiya |
|---|---|
| Country | India |
| Abstract | This paper proposes a method of retaining high enough voltage on the terminal of DFIG wind turbines during a fault interval on the connected grid. This method is developed by the ideal of dynamic voltage restorer equipment and was applied to a wind turbines group. The DC-link and the grid side converter of the first DFIG wind turbine in this group are utilized to support the other wind turbines. The converter is connected to a transformer, which is in series with the wind turbine group and the connected line, during an external fault. At the DC-link of the back-to-back converter of each DFIG wind turbine, a DC chopper is equipped to dissipate excessive active power during the fault interval. Moreover, the controllers of all wind turbines are modified to support all wind turbines in the group. The method is verified by MATLAB/Simulink. Simulation results implied that the proposed method can retain a high enough voltage on the terminal of DFIG while preventing overcurrent on the rotor side. |
| Keywords | DFIG; DVR; fault-ride-through capability; voltage enhancement; wind turbine |
| Field | Engineering |
| Published In | Volume 8, Issue 5, September-October 2026 |
| Published On | 2026-10-18 |
| DOI | https://doi.org/10.36948/ijfmr.2026.v08i05.88563 |
Share this

E-ISSN 2582-2160
CrossRef DOI prefix of IJFMR is 10.36948/ijfmr
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
Powered by Sky Research Publication and Journals