International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
Conferences Published ↓
ISC-AISGF-TBRF
DePaul-2026
IC-AIRCM-T3-2026
NSSFIGTMA-2025
SPHERE-2025
AIMAR-2025
SVGASCA-2025
ICRTET-4
ICCE-2025
Chinai-2023
PIPRDA-2023
ICMRS'23
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 8 Issue 6
November-December 2026
Indexing Partners
Space-Based versus Land-Based AI Data Centres: A Comparative Environmental Assessment Centred on Google's Orbital Compute Programme
| Author(s) | Prof. Dr. Vijayalaxmi Rajiv Shinde, Mr. Rajiv Shinde |
|---|---|
| Country | India |
| Abstract | This paper compares space-based AI compute against terrestrial hyperscale data centres across six environmental parameters, using Google's published research programme on solar-powered TPU constellations in dawn-dusk low-Earth orbit as the reference case (Arcas et al., 2025). The comparison uses a dual functional unit — 1 MW-year of delivered IT power, and 1 MW of IT power over 1-, 5- and 10-year missions — under a cradle-to-grave boundary that includes launch and re-entry for the orbital case. Three findings emerge. First, the carbon result is functional-unit dependent: per kWh of energy delivered to the payload, orbital systems are 1.5–1.95× more carbon-intensive than terrestrial ones (52.1–66.3 versus 34.0 gCO₂e/kWh) (Ohs et al., 2025); but per MW of IT capacity against real-world grids, launch-phase emissions of 1,032–2,585 t CO₂e are repaid within the first year and amount to only 5.5–13.7% of five years of terrestrial operation at the 395.65 gCO₂e/kWh global data-centre average (Vries-Gao, 2025). Break-even occurs at grid intensities of 21.6–54.1 gCO₂e/kWh over five years. Second, water and land are where space wins categorically: no evaporative cooling, and no terrestrial land conversion of the tens-to-hundreds of hectares a hyperscale facility requires (Hlabisa, 2025). Third, the binding physical constraint in orbit is not compute silicon but radiative heat rejection — 33–67 cm² of radiator per watt of waste heat, or 3,333–6,667 m² per MW (Vicente, 2021) — which converts thermal inefficiency directly into launch mass and launch carbon. |
| Keywords | orbital data centres; data centre sustainability; water usage effectiveness; radiative cooling; life-cycle assessment; re-entry emissions |
| Field | Computer > Artificial Intelligence / Simulation / Virtual Reality |
| Published In | Volume 8, Issue 6, November-December 2026 |
| Published On | 2026-11-05 |
| DOI | https://doi.org/10.36948/ijfmr.2026.v08i06.91339 |