International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
Conferences Published ↓
ISC-AISGF-TBRF
DePaul-2026
IC-AIRCM-T3-2026
NSSFIGTMA-2025
SPHERE-2025
AIMAR-2025
SVGASCA-2025
ICRTET-4
ICCE-2025
Chinai-2023
PIPRDA-2023
ICMRS'23
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 8 Issue 6
November-December 2026
Indexing Partners
Design, Integration and Experimental Performance Evaluation of a Hybrid Solar–Battery Power System for a 12 V DC Tyre-Inflation Compressor
| Author(s) | Samuel Owusu-Ansah, Lugman Ebow Ibn Daud, Alex Ampofo, Daniel Apraku, Samuel Adu- Gyamfi |
|---|---|
| Country | Ghana |
| Abstract | A standalone hybrid solar–battery power system was designed, assembled and experimentally evaluated as an alternative electrical supply for a 12 V DC tyre-inflation compressor. The prototype comprised a nominal 120 W DC reciprocating compressor, a 175 W monocrystalline photovoltaic (PV) module, a 12 V, 40 Ah deep-cycle battery and a 20 A maximum-power-point-tracking charge controller. The performance of the system was investigated under battery-only and solar-assisted operating conditions using three tyre sizes: 225/70R16, 185/70R14 and 175/65R14. The reported mean inflation times under battery-only operation were 288.3, 261.7 and 251.7 s, respectively, compared with 350.0, 301.7 and 285.0 s under solar-assisted operation. The maximum pressures attained were 35 psi and 30 psi for battery-only and solar-assisted operation, respectively. Battery endurance tests recorded operating durations of 30 and 25 min, corresponding to five and four tyre-inflation operations. The measured electrical input powers were reported as 91.46 W and 75.05 W for battery-only and solar-assisted operation, respectively. Compressor temperature increased from 29.4 °C to 41.3 °C during 15 min of continuous operation. The results demonstrate the practical integration of a photovoltaic charging system, battery storage and a small DC compressor. However, differences in attainable pressure and unresolved electrical measurement conditions highlight the need for further experimental validation before comparative energy-performance claims can be established. |
| Keywords | photovoltaic system; battery storage; DC air compressor; tyre inflation; hybrid power supply; experimental performance |
| Field | Engineering |
| Published In | Volume 7, Issue 2, March-April 2025 |
| Published On | 2025-04-18 |
Share this

E-ISSN 2582-2160
CrossRef DOI prefix of IJFMR is 10.36948/ijfmr
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
Powered by Sky Research Publication and Journals